Stimulation Results
- Pad Treating Pressure - value of Surface Treating Pressure for the time Proppant Concentration is zero but next step is not zero. calculated as
PTP = Ceiling[STP/1000]
example: Surface Treating Pressure = 1500, -> Pad Treating Pressure = 2
- Pad Delta Treating Pressure we should detect the difference in the pressure between the first moment you start pumping and the last moment before you start pumping proppant (e.g., 0 to 200 psi difference = 1, 200psi to 400psi difference = 2 etc.).
- Proppant Placed Score Assign a score based on the percentage of the original design proppant pumped (e.g., 0 to 20% = 1… 80% to 100% = 5, 100% + = 6 etc.).
- Sweep Score Assign a score based on the number of unscheduled steps pumped compared to the design… i.e. the number of “merged” steps that DWK is implementing now in the F6 screen!
- Time Score Assign a score based on the total time the job took to pump (e.g., 0 to 100 minutes = 1, 100 minutes to 150 minutes = 2 etc.).
- Total Fluid Score Assign a score based on the amount of fluid total
- Max Prop Conc Score Assign a score based on the max prop con
- Fluid Type Score Assign a score based on what percentage of a particular fluid was used (more crosslink, higher difficulty score)
- Additive Type Score Assign a score based on the average concentration of a particular additive (e.g., FR)